| Ongoing Project » MF Jayaram |
| |
|
|
|
| MF Jayaram Enclave - Project Specifications |
|
| |
| STRUCTURE |
: |
R.C.C. Framed Structure. 9” brickwork for Outer walls. |
| |
|
|
| DOORS |
: |
Entrance door - teak wood frames and fiber moulded skin door with French polish finish. 1st quality country wood frames with Flush shutters for all internal doors [as per Architect’s Design]. |
| |
|
|
| WINDOWS |
: |
Aluminum / UPVC openable or sliding windows. |
| |
|
|
| KITCHEN |
: |
a. Polished Black Granite 19mm thick for Platform over a RCC slab with edge nosing.
b. Stainless steel sink with Drain Board with single bowl.
c. Glazed tiles for walls up to 2’-0” above kitchen platform. |
| |
|
|
| BED ROOM |
: |
Bedrooms shall have a space for built-in open Wardrobe and Open Loft. |
| |
|
|
| BATH ROOM |
: |
The following amenities are provided in each bathroom,
1) Antiskid Ceramic tiles for floors.
2) Glazed tiles for walls up to 7ft.ht.
3) European water closet with slim line water tank for all bathrooms –white colour.
4) CP fittings & Shower
5) Wash Basin for all bathrooms – white colour.
6) Geyser provision for all toilets.
7) Health Faucet |
| |
|
|
| PAINTING |
: |
a. Asian Ace /Equivalent Exterior Emulsion for outside walls.
(Architect choice )
b. Asian Tractor Emulsion /equivalent for inside walls.
(Architect choice).
c. Enamel painting for grills, doors & windows.
d. Wood polishing for the main door. |
| |
|
|
| ELECTRICAL |
: |
- Concealed wiring using PVC conduits recessed Switch boards with Modular switches, three phase power with Independent meter.
- Inverter provision (General).
- Provision for TV / Broadband.
|
| |
|
|
| WATER SUPPLY |
: |
Common Bore Well, Overhead Tank and Sump With 12000 liters capacity. |
| |
|
|
| SANITATION |
: |
All Sanitary waste to be taken through 4” PVC 6KG pipe to manhole chambers and then to Septic Tank. |
| |
|
|
| PLUMBING FITTINGS |
: |
PARRYWARE or equivalent |
OTHERS |
: |
Any extra works will not be done.
Structural Changes, Elevation Changes, Grill Design Changes, colour scheme changes will not be Entertained.
|
|
|
| ELECTRICAL POINTS WITHOUT FITTINGS |
| Place |
Light |
Tube |
Fan |
Plug |
Others |
| Hall cum Dining |
2 Nos. |
2 Nos. |
2 Nos. |
5 Amps – 3 Nos.
Fridge Point – 1 No. |
Telephone – 1 No.
T.V. Point – 1 No. |
Master
Bed Room |
1 Nos. |
1 No. |
1 No. |
5 Amps – 2 Nos.
Foot Lamp – 1 No. |
A/C Point –1 No. Telephone – 1 No.
T.V. Point – 1 No. |
| 2nd Bed Room |
1 Nos. |
1 No. |
1 No. |
5 Amps – 2 Nos.
Foot Lamp –1 No. |
A/C Point –1 No. |
| Bath |
2 Nos. |
- |
- |
5 Amps-1 No.
Geyserpoint-1 No.
|
Exhaust Fan Point-1No. |
| Kitchen |
1 No. |
1 No. |
- |
15 Amps-1 No.
5 Amps-2Nos. |
Exhaust Fan Point-1No. |
| Service Area |
1 No. |
- |
- |
Washing Machine point –1No.
Where the provision is given
|
- |
| Sit out Area |
1 No. |
- |
- |
|
- |
|
|
|
 |
|
|
|
|